Translate

Thursday, 22 May 2014

Younger Age Is Associated with a Higher Risk of Early Periprosthetic Joint Infection and Aseptic Mechanical Failure After Total Knee Arthroplasty

Although early aseptic mechanical failure after total knee arthroplasty has been reported in younger patients, it is unknown whether early revision due to periprosthetic joint infection is more or less frequent in this patient subgroup. The purpose of this study was to determine whether the incidence of early periprosthetic joint infection requiring revision knee surgery is significantly different in patients younger than fifty years of age compared with older patients following primary unilateral total knee arthroplasty.

Methods: 
A large population-based study was conducted with use of the California Patient Discharge Database, which allows serial linkage of all discharge data from nonfederal hospitals in the state over time. Patients undergoing primary unilateral total knee arthroplasty during 2005 to 2009 were identified. Principal outcomes were partial or complete revision arthroplasty due to periprosthetic joint infection or due to aseptic mechanical failure within one year. Multivariate analysis included risk adjustment for important demographic and clinical variables. The effect of hospital total knee arthroplasty volume on the outcomes of infection and mechanical failure was analyzed with use of hierarchical modeling.

Results: 
At one year, 983 (0.82%) of 120,538 primary total knee arthroplasties had undergone revision due to periprosthetic joint infection and 1385 (1.15%) had undergone revision due to aseptic mechanical failure. The cumulative incidence in patients younger than fifty years of age was 1.36% for revision due to periprosthetic joint infection and 3.49% for revision due to aseptic mechanical failure. In risk-adjusted models, the risk of periprosthetic joint infection was 1.8 times higher in patients younger than fifty years of age (odds ratio = 1.81, 95% confidence interval = 1.33 to 2.47) compared with patients sixty-five years of age or older, and the risk of aseptic mechanical failure was 4.7 times higher (odds ratio = 4.66, 95% confidence interval = 3.77 to 5.76). The rate of revision due to infection at hospitals in which a mean of more than 200 total knee arthroplasties were performed per year was lower than the expected (mean) value (p = 0.04).

Conclusions: 
Patients younger than fifty years of age had a significantly higher risk of undergoing revision due to periprosthetic joint infection or to aseptic mechanical failure at one year after primary total knee arthroplasty.

Wednesday, 9 April 2014

Fat with 20 - knee replacement with 60?

Previous studies could demonstrate the positive relationship between obesity and earlier hip replacement. This study focussed on the association between weight gain and the risk of knee replacement (KR) due to primary osteoarthritis (OA), and to evaluate whether the association differs by age.

225,908 individuals from national health screenings with repeated measurements of height and weight were followed prospectively with respect to KR identified by linkage to the Norwegian Arthroplasty Register. Cox proportional hazard regression was used to calculate sex-specific relative risks (RR) of KR according to change in Body Mass Index (BMI) and weight, corresponding analyses were done for age categories at first screening.

It was found that during 12 years of follow up, 1591 participants received a KR due to primary OA. Men in the highest quarter of yearly change in BMI had a RR of 1.5 (95% confidence interval (CI) 1.1-1.9) of having a KR compared to those in the lowest quarter. For women the corresponding RR was 2.4 (95% CI 2.1-2.7). Men under the age of 20 at the first screening had a 26% increased risk for KR per 5 kg weight gain, for women the corresponding increase was 43%. At older age the association became weaker, and in the oldest it was lost.

As a result, the authors concluded that weight gain increases the risk for later KR both in men and women. The impact of weight gain is strongest in the young, at older age the association is weak or absent. Our study suggests that future OA may be prevented by weight control and that preventive measures should start at an early age.





Tuesday, 4 March 2014

Dom't feel safe with double gloving!


INTRODUCTION
Surgical gloves provide a protective barrier against blood borne pathogens such as human immunodeficiency virus, hepatitis B and hepatitis C. Glove perforation occurs frequently – in some types of surgery at a rate of up to 45%, but is often unnoticed by the surgeon and nurse. One estimate suggested that a surgeon risks more than one hepatitis infection per lifetime and more than one in 1,500 surgeons is likely to be infected by HIV during the next 35 years because of
damaged gloves.

One study has concluded that the use of a double gloving system featuring a colored under-glove gives an accuracy of detection of 97%.This study therefore aimed to compare puncture rates between this double gloving indicator system and single-use gloves. It also aimed to determine the extent to which glove perforations remain undetected during surgery.

METHOD
The study analyzed all gloves used at the Satakunta Central Hospital, Pori, Finland in
September and October 1999. The study was open and prospective and randomization was
made according to the year of birth of the patient – patients born in even years were operated on
with double gloving and those born in odd years were operated on with single gloving. Gloves were tested using the approved standardized water-leak test method EN455-1 where the glove is filled with water and checked for two minutes to detect any holes.The gloves used in the study were either Biogel Indicator™ or Gammex and Nutex, which were the standard gloves used at the
hospital.

An analysis was made according to glove type, operating time, surgeon or assistant and type
of surgery. A comparison was also made to see whether or not glove perforation was noticed
during the operation.

RESULTS
In a total of 885 surgical procedures 2,462 gloves were tested – 1,020 single gloves, 1,148 double glove systems and 294 combination gloves were studied. The overall perforation rate was 192 out of 2,462 gloves (7.8%) or 162 out of 885 operations (18.3%). The inner glove of the double-gloving system was punctured in 6 out of 88 (6.8%) outer glove perforations. Detection of perforation during surgery was 28 out of 76 (36.8%) with single gloves, 77 out of 89 (86.5%) with the double gloving system and 9 out of 27 (33.3%) with combination gloves.

CONCLUSION & COMMENT
The authors conclude that in order to maintain a sterile barrier between surgeon and patient it is important to use a double gloving puncture indication system, particularly in operations where there is a high risk of glove perforation.




Thursday, 23 January 2014

Complications After Arthroscopic Knee Surgery

Background: Knee arthroscopies are among the most common procedures performed by orthopaedic surgeons, yet little is known about the associated complications and complication rates. 

Purpose: To examine the nature and frequency of complications after the most common arthroscopic knee procedures, with particular attention to fellowship training, geographic location of practice, and age and sex of the patient. 

Study Design: Cross-sectional study; Level of evidence, 3. 

Methods: Data were obtained from the American Board of Orthopaedic Surgery database for orthopaedic surgeons who sat for the part II examination from 2003 to 2009. The database was queried to determine the type and frequency of complications for patients who underwent knee arthroscopy and for those who underwent sports medicine knee arthroscopy, including arthroscopic partial meniscectomy, meniscal repair, chondroplasty, microfracture, anterior cruciate ligament reconstruction, or posterior cruciate ligament reconstruction. Factors affecting complication rates that were investigated included type of procedure, fellowship training status, geographic location of practice, and age and sex of the patient. 

Results: There were 4305 complications out of 92,565 knee arthroscopic procedures obtained from the American Board of Orthopaedic Surgery database for an overall candidate-reported complication rate of 4.7%. The complication rates were highest for posterior cruciate ligament reconstruction (20.1%) and anterior cruciate ligament reconstruction (9.0%); complication rates for meniscectomy, meniscal repair, and chondroplasty were 2.8%, 7.6%, and 3.6%, respectively. The complication rate for sports fellowship–trained candidates was higher than for non–sports trained candidates (5.1% sports, 4.1% no sports; P < .0001) and for male patients (4.9% male vs 4.3% female; P < .0001). Younger patients (<40 years; 6.2%) had a higher complication rate than older patients (≥40 years; 3.58%) (P < .0001). Procedure complexity is a likely confounding factor affecting sports-trained candidates and younger patients. There were no geographic differences (P = .125). The overall rate of pulmonary embolus was 0.11%. Surgical complications (3.68%) were more common than medical (0.77%) or anesthetic complications (0.22%), and infection was the most common complication overall (0.84%). 

Conclusion: The overall self-reported complication rate for arthroscopic knee procedures was 4.7%. Knee arthroscopy is thought not to be a benign procedure, and patients should be made aware of the risk of complications. 


Comment:
Please note that the article reflects the figures for fellowship trainees. They may be different in the group of a specialised surgeon. However, the range of complications and their proportions may be the same.

  

Friday, 10 January 2014

"Red flags" under fire

Most clinical practice guidelines for back pain recommend the use of red flags to help identify those patients with a higher likelihood of spinal fracture or malignancy who then become candidates for more extensive diagnostic investigations. There is confusion, however, as the guidelines have produced different lists of red flags to screen for spinal fracture and malignancy. Eight of the guidelines investigated by Koes and colleagues in their review of back pain guidelines, endorsed 26 red flags for fracture and 27 for malignancy. 

None of the eight guidelines endorsed the same set of red flags, for either condition, so it is unclear what clinicians should use in clinical care. Additionally, guidelines generally provide no information on diagnostic accuracy of the endorsed red flags, which limits their value in clinical decision making. Adding to the uncertainty, the same agency can provide inconsistent information on red flags. For example, the National Institute for Health and Care Excellence clinical guideline on the early management of persistent non-specific low back pain does not endorse red flags, whereas the group’s clinical knowledge summary for the management of low back pain does
To resolve the uncertainty around application of red flags in clinical practice, the authors conducted two Cochrane diagnostic test accuracy reviews assessing the accuracy of red flags to screen for the most common forms of serious pathology—spinal fracture and malignancy—in patients with low back pain. They have provided a distilled summary of both reviews to help guide clinical decision making.

Objective To review the evidence on diagnostic accuracy of red flag signs and symptoms to screen for fracture or malignancy in patients presenting with low back pain to primary, secondary, or tertiary care.

Design Systematic review.

Data sources Medline, OldMedline, Embase, and CINAHL from earliest available up to 1 October 2013.

Inclusion criteria Primary diagnostic studies comparing red flags for fracture or malignancy to an acceptable reference standard, published in any language.

Review methods Assessment of study quality and extraction of data was conducted by three independent assessors. Diagnostic accuracy statistics and post-test probabilities were generated for each red flag.

Results We included 14 studies (eight from primary care, two from secondary care, four from tertiary care) evaluating 53 red flags; only five studies evaluated combinations of red flags. Pooling of data was not possible because of index test heterogeneity. Many red flags in current guidelines provide virtually no change in probability of fracture or malignancy or have untested diagnostic accuracy. The red flags with the highest post-test probability for detection of fracture were older age (9%, 95% confidence interval 3% to 25%), prolonged use of corticosteroid drugs (33%, 10% to 67%), severe trauma (11%, 8% to 16%), and presence of a contusion or abrasion (62%, 49% to 74%). Probability of spinal fracture was higher when multiple red flags were present (90%, 34% to 99%). The red flag with the highest post-test probability for detection of spinal malignancy was history of malignancy (33%, 22% to 46%).

Conclusions While several red flags are endorsed in guidelines to screen for fracture or malignancy, only a small subset of these have evidence that they are indeed informative. These findings suggest a need for revision of many current guidelines.


Read the article:
BMJ 2013;347:f7095 BMJ 2013; 347 doi: http://dx.doi.org/10.1136/bmj.f7095 (Published 11 December 2013). 

Friday, 3 January 2014

Excise or save: Do we need a fat pad?


The infrapatellar fat pad is one of the structures that obscures exposure in minimally invasive total knee arthroplasty (MIS TKA). Most MIS TKA surgeons (and many surgeons who use other approaches as well) excise the fat pad for better exposure of the knee. There is still controversy about the result of fat pad excision on patella baja, pain, and function.

QUESTIONS/PURPOSES:
In the setting of a randomized controlled trial, we sought to determine whether infrapatellar fat pad excision during MIS TKA causes (1) patellar tendon shortening (as measured by patella baja); (2) increased anterior knee pain; (3) decreases in the Knee Society Score or functional subscore; or (4) more patella-related complications.

METHODS:
We randomized 90 patients undergoing MIS TKA at one institution into two groups. In one group, 45 patients underwent MIS TKA with complete infrapatellar fat pad excision and in the other group, 45 patients received MIS TKA without infrapatellar fat pad excision. The patella was selectively resurfaced in these patients; there was no difference between the groups in terms of the percentage of patients whose patellae were resurfaced. We measured patellar tendon shortening, knee flexion, anterior knee pain, Knee Society Score (KSS), functional subscore, and patellar complications at preoperative and postoperative periods of 6 weeks, 3 months, 6 months, and 1 year; complete followup data were available on 86% of patients (77 of 90) who were enrolled.

RESULTS:
At the final followup, no significant differences were observed in patellar tendon shortening, KSS, functional subscore, or knee flexion in either group. However, patients with their infrapatellar fat pad excised experienced more anterior knee pain (8.3% versus 0%; p = 0.03; 95% confidence interval, -0.007 to 0.174) at the end of the study. No patellar complications were found in either group.

CONCLUSIONS:
Infrapatellar fat pad excision in MIS TKA resulted in an increasing small percentage of patients with anterior knee pain after surgery. Surgeons should keep the fat pad if excellent exposure can be achieved but resect it if needed to improve exposure during TKA.

LEVEL I OF EVIDENCE:


 Pinsornsak P, Naratrikun K, Chumchuen S:The Effect of Infrapatellar Fat Pad Excision on Complications After Minimally Invasive TKA: A Randomized Controlled Trial. Clin Orthop Relat Res. 2013 Oct 18.

Thursday, 12 December 2013

Mortality rates at 10 years after metal-on-metal hip resurfacing compared with total hip replacement in England: retrospective cohort analysis of hospital episode statistics

Objectives To compare 10 year mortality rates among patients undergoing metal-on-metal hip resurfacing and total hip replacement in England.
Design Retrospective cohort study.
Setting English hospital episode statistics database linked to mortality records from the Office for National Statistics.

Population All adults who underwent primary elective hip replacement for osteoarthritis from April 1999 to March 2012. The exposure of interest was prosthesis type: cemented total hip replacement, uncemented total hip replacement, and metal-on-metal hip resurfacing. Confounding variables included age, sex, Charlson comorbidity index, rurality, area deprivation, surgical volume, and year of operation.

Main outcome measures All cause mortality. Propensity score matching was used to minimise confounding by indication. Kaplan-Meier plots estimated the probability of survival up to 10 years after surgery. Multilevel Cox regression modelling, stratified on matched sets, described the association between prosthesis type and time to death, accounting for variation across hospital trusts.

Results 7437 patients undergoing metal-on-metal hip resurfacing were matched to 22 311 undergoing cemented total hip replacement; 8101 patients undergoing metal-on-metal hip resurfacing were matched to 24 303 undergoing uncemented total hip replacement. 10 year rates of cumulative mortality were 271 (3.6%) for metal-on-metal hip resurfacing versus 1363 (6.1%) for cemented total hip replacement, and 239 (3.0%) for metal-on-metal hip resurfacing versus 999 (4.1%) for uncemented total hip replacement. Patients undergoing metal-on-metal hip resurfacing had an increased survival probability (hazard ratio 0.51 (95% confidence interval 0.45 to 0.59) for cemented hip replacement; 0.55 (0.47 to 0.65) for uncemented hip replacement). There was no evidence for an interaction with age or sex.

Conclusions Patients with hip osteoarthritis undergoing metal-on-metal hip resurfacing have reduced mortality in the long term compared with those undergoing cemented or uncemented total hip replacement. This difference persisted after extensive adjustment for confounding factors available in our data. The study results can be applied to matched populations, which exclude patients who are very old and have had complex total hip replacements. Although residual confounding is possible, the observed effect size is large. These findings require validation in external cohorts and randomised clinical trials.

 BMJ 2013;347:f6549
 http://www.bmj.com/content/347/bmj.f6549